Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.061
Filtrar
1.
J Oral Implantol ; 50(1): 24-30, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579113

RESUMO

Alveolar bone quality at the implantation site affects the initial stability of dental implant treatment. However, the relationship between bone quality and osseointegration has yet to be evaluated. Herein, we aimed to investigate the effect of bone quality on dental implant stability in osseointegration formation changes. Patients underwent computed tomography imaging before dental implantation at the posterior. Hounsfield units were measured at the platform, middle, and tip sites. Implant stability was measured using resonance frequency analysis immediately and at 3 months postoperatively, in which the difference in implant stability quotients (ISQ) was defined as the change between primary and secondary fixation. In multiple regression analysis, the dependent variable was the change between the immediate and secondary fixations. We included 81 implants that conformed to the criteria. Primary fixation yielded the following results: R2 = 0.117, F = 2.529, and P = .047. The difference between the maxilla and mandible of the implantation site (P = .02) and the platform-site Hounsfield units (P = .019) were identified as significant factors. The following results were obtained regarding the change between the immediate and secondary fixation: R2 = 0.714, F = 40.964, and P < .001. The difference between diameter (P = .008) and the immediate ISQ (P < .001) were identified as significant factors. Overall, the bone quality of the implantation site affected initial fixation; however, it had limited effect on secondary fixation. Our findings clarified the period where bone quality affects dental implant treatment and is expected to advance dental implant treatment.


Assuntos
Implantes Dentários , Humanos , Implantação Dentária Endóssea/métodos , Densidade Óssea , Osseointegração , Tomografia Computadorizada por Raios X , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Maxila/diagnóstico por imagem , Maxila/cirurgia
2.
J Oral Implantol ; 50(1): 31-38, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579114

RESUMO

The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.


Assuntos
Implantes Dentários , Torque , Dente Suporte , Análise do Estresse Dentário , Retenção em Prótese Dentária , Projeto do Implante Dentário-Pivô
3.
Biomed Tech (Berl) ; 69(1): 1-10, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37489593

RESUMO

OBJECTIVES: To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). CONTENT: Methods to evaluate the stability of dental implants. SUMMARY: A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined "resonance frequency analysis" and "Periotest" with "correlation" or "relationship"; and combinations of "implant stability quotient" and "Periotest" with "correlation" or "relationship." The inclusion criteria were clinical studies in English involving human subjects who received dental implants and evaluating the correlation between PTV and ISQ. A total of 46 articles were screened, of which 10 were selected for full-text analysis, and eight articles were included in this review. Based on three articles, 75 % of the results of this systematic review showed a negative correlation between PTV and ISQ, regardless of the type of stability assessed. Based on the remaining five articles, 100 % (regardless of the patient's gender) and 66.66 % of the results showed a negative correlation for primary and secondary stability, respectively. There is a negative correlation between PTV and ISQ for both primary and secondary dental implant stability. OUTLOOK: This review can serve as a reference for the development of methodologies for future clinical studies on this topic.


Assuntos
Implantes Dentários , Osseointegração , Humanos , Implantação Dentária Endóssea , Retenção em Prótese Dentária
4.
Clin Oral Implants Res ; 35(1): 1-20, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37840388

RESUMO

INTRODUCTION: The radiographic examination of alveolar bone using 3D radiographic examination is essential in dental implant treatment planning. Our study aimed to systematically review and quantitatively analyze the correlation between alveolar bone parameters, specifically bone density and cortical bone thickness, assessed using cone beam computed tomography (CBCT) and/or multidetector computed tomography (MDCT); and primary implant stability (PIS) determined using implant stability quotient (ISQ), Periotest® value (PTV), and insertion torque value (ITV). METHODS: This review was registered in the PROSPERO database (registration number CRD42022307245). An electronic literature search was conducted on the PubMed, SCOPUS, and Web of Science databases for papers published until February 2022. The Quality Assessment in Prognostic Studies (QUIPS) tool was used to assess risk of bias. Meta-analyses were conducted to calculate the estimated average correlation coefficient based on a multilevel random-effects model, followed by subgroup analysis. RESULTS: Twenty-six studies were included in this review, consisting of 17 prospective cohort studies, eight retrospective cohort studies, and one nonrandomized controlled trial. A total of 3109 implants placed in 1171 subjects were analyzed. Twenty-three studies were evaluated using meta-analysis. The alveolar bone condition was significantly correlated with ISQ (r = 0.60; p < .001), IT (r = 0.52; p < .001), and PTV (r = -0.42; p < .05). CONCLUSION: Alveolar bone condition is significantly associated with PIS. Low bone density and thin cortical bone can lead to low PIS; therefore, modification of treatment planning and surgical procedures might be needed to avoid poor osseointegration.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Humanos , Implantação Dentária Endóssea/métodos , Estudos Retrospectivos , Estudos Prospectivos , Retenção em Prótese Dentária , Densidade Óssea , Torque
5.
Int J Periodontics Restorative Dent ; 43(4): e165-e172, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37552194

RESUMO

Adequate implant primary stability is a key factor to obtain osseointegration and can be measured at insertion by insertion torque (IT) and at different timepoints with resonance frequency analysis (RFA), expressed as an implant stability quotient (ISQ). This retrospective study investigated the correlation between ISQ and IT at implant insertion. All patients who were eligible for this single-cohort retrospective clinical trial were treated with an immediate implant. IT parameters were recorded at implant insertion, and ISQ values were recorded at insertion and at 2-, 4-, and 12-month follow-ups. The study comprised 23 patients who received 32 implants. The mean IT value was 46.87 ± 9.66 Ncm (range: 25 to 65 Ncm), and the mean ISQ value at implant insertion was 71.45 ± 4.24 (range: 63 to 78); these values showed a statistically significant correlation (P < .0001). According to the present data and considering the implant design used in this trial, there is a statistically significant and positive correlation between IT and ISQ values. Thus, ISQ can be used as a reliable method to measure implant stability over time.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Humanos , Implantação Dentária Endóssea/métodos , Retenção em Prótese Dentária , Osseointegração , Análise de Frequência de Ressonância , Estudos Retrospectivos , Torque
6.
J Oral Implantol ; 49(4): 347-354, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37527177

RESUMO

Primary implant stability (PIS) is known to vary with recipient bone mass and density, dental implant design and surgical technique. The objective of this preliminary study was to compare rotational and lateral PIS of same-coronal-diameter conical and parallel implants, using insertion torque recorded with a dental implant motor set and implant stability quotient obtained from resonance frequency analysis (performed with both Osstell and Penguin systems) as measures of rotational and lateral stability, respectively. Additionally, the relationship between PIS and alveolar ridge width (ARW) was explored in both implant types. Sixty dental implants (30 tapered and 30 parallel) were randomly placed with a split-mouth design in 17 patients. Bone density and ARW were estimated from cone beam computed tomography images taken with radiological-surgical templates. Density and width values were similar in the 2 groups (P > .05). Implant coronal diameters were 3.75 mm in all cases, while consistent with the manufacturer's recommendations, final drill bit diameters used were 3.25 and 3.4 mm for parallel and tapered implants, respectively. Insertion torque was higher (P < .05) with parallel implants, but between-group differences in implant stability quotient were not significant (P > .05). In tapered implants, insertion torque was inversely correlated with ARW (P < .001). Notably, significant differences were observed between resonance frequency analysis values from Osstell and Penguin systems (P < .001). In conclusion, future studies should explore how PIS may be influenced by final drill bit size regardless of implant design and potential limits on the effectiveness of tapered implants to achieve good stability in thick low-density bone.


Assuntos
Implantes Dentários , Humanos , Implantação Dentária Endóssea/métodos , Análise de Frequência de Ressonância , Torque , Densidade Óssea , Processo Alveolar , Planejamento de Prótese Dentária , Retenção em Prótese Dentária
7.
Int J Oral Maxillofac Implants ; 38(2): 334-337, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37083906

RESUMO

Purpose: To evaluate primary stability of a new dental implant design in low-density bone sites, compare it with another implant design previously studied in the same bone density, and explore possible correlations between primary stability parameters. Materials and Methods: The study was carried out on fresh humid bovine bone classified as type III. The test group consisted of 30 DS Prime Taper implants (PT), and the control group consisted of 30 Astra Tech EV implants (EV). All the implants were inserted according to the protocol provided by the manufacturer. After placement, variable torque work (VTW), peak insertion torque (pIT), and resonance frequency analysis (RFA) were recorded. Results: Mann-Whitney test showed that the mean VTW and pIT were significantly higher in the test group PT compared to the control group EV; furthermore, statistical analysis showed that the mean RFA was slightly higher in the control group EV but without reaching statistical significance. Pearson correlation analysis showed a very strong positive correlation between pIT and VTW values in both groups; furthermore, it showed a positive correlation between pIT and RFA values and between VTW and RFA values again in both groups. Conclusion: The results showed that the novel tapered implants were able to reach good primary stability in low-density bone sites and that this was superior to parallel-walled implants when measured with VTW and pIT. Moreover, a statistically significant correlation was found between the three methods used to measure implant primary stability.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Animais , Bovinos , Implantação Dentária Endóssea/métodos , Torque , Densidade Óssea , Análise de Frequência de Ressonância , Planejamento de Prótese Dentária , Retenção em Prótese Dentária
8.
J Prosthet Dent ; 130(1): 35-47, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34740460

RESUMO

STATEMENT OF PROBLEM: Screwmentable prostheses were developed to combine the benefits of screw retention and cement retention. However, data are limited on the clinical performance of this type of prosthesis. PURPOSE: The purpose of this systematic review was to collect scientific evidence on screwmentable prostheses and evaluate their long-term clinical behavior. MATERIAL AND METHODS: An electronic search was conducted by 2 independent reviewers for articles published in scientific dental journals in English from 2004 to April 2020. The search strategy followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Inclusion criteria were scientific studies concerning the screwmentable type of prosthesis. RESULTS: The search provided 494 records. Of these, 24 studies fulfilled the inclusion criteria and were included in the review. The included articles presented significant heterogeneity concerning the manufacturing process and the materials used. One randomized clinical trial, 2 prospective clinical studies, 14 in vitro studies, 3 protocol descriptions, 1 case series, and 3 case reports were included. CONCLUSIONS: Based on the systematic search of the literature, it is concluded that the screwmentable prosthesis combines advantages of both cement-retained and screw-retained restorations, including passive fit, retrievability, excess cement control, tissue-friendly emergence profile, and improved esthetics. Nevertheless, data from well-designed clinical trials are limited, and further research is required to provide evidence on their long-term clinical behavior.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária/métodos , Estudos Prospectivos , Prótese Dentária Fixada por Implante/métodos , Estética Dentária , Cimentos Dentários/uso terapêutico , Cimentos de Ionômeros de Vidro , Ensaios Clínicos Controlados Aleatórios como Assunto
9.
J Prosthet Dent ; 130(1): 48-58, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34809995

RESUMO

STATEMENT OF PROBLEM: Different techniques for retrieving cement-retained implant-supported prostheses have been described to minimize damage to the prostheses. Nevertheless, a classification of the described techniques remains ambiguous. PURPOSE: The purpose of this systematic review was to review and classify the described techniques for recording and locating the screw access hole in cement-retained implant-supported prostheses. MATERIAL AND METHODS: A bibliographic search was completed on MEDLINE/PubMed, Web of Science, Scopus, and Cochrane databases. A manual search was also conducted. The articles that described or evaluated techniques for recording and locating the screw access hole of cement-retained implant-supported prostheses were included. Two investigators independently assessed the quality assessment of the studies using the Revised Cochrane risk of bias tool for randomized trials. A third examiner was consulted to resolve the lack of consensus. RESULTS: A total of 30 articles were included. The different methods were classified according to whether the screw access hole location was registered before or after cementation. The precementation techniques were classified into 4 subgroups: identification marks, photographic records, digital files, and precementation screw access hole location guides. The postcementation techniques were subdivided into 2 subgroups: radiographic records and postcementation screw access hole location guides. CONCLUSIONS: Different techniques have been proposed to facilitate the location of the screw access hole in cement-retained implant-supported restorations. Although the evidence is scarce, studies seem to ascertain that some techniques, such as the use of drilling guides, orientation with cone beam computed tomography images, or holes made in the metal framework, can increase the retrievability of cement-retained implant-supported prostheses and decrease complications in the location of the screw access hole. The proposed classification summarizes precementation and postcementation techniques and provides a tool to decide the most suitable for each specific clinical situation.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante/métodos , Retenção em Prótese Dentária/métodos , Cimentos Dentários/uso terapêutico , Cimentação/métodos , Cimentos de Ionômeros de Vidro , Parafusos Ósseos
10.
J Esthet Restor Dent ; 34(8): 1147-1155, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36052667

RESUMO

BACKGROUND: The prosthetic screw fixes the prostheses to the implants. Upon osteointegration, the untightening of the prosthetic screw is the most common problem in oral rehabilitation with implants. OBJECTIVE: To study the deformation of the implant retaining hexagonal screw head. METHODS: This investigation used two methods for evaluating the screw head's area of deformation (mm2 ): a stereoscopic microscopy and micro computed tomography (microCT). For stereoscopic microscopy, 16 titanium alloy (T) and 16 titanium gold-plated alloy (G) screws of the Zimmer Biomet™ brand were used, divided into eight groups: group 0 (control group), groups T1 and G1 (screws tightened 10 times to 20 Ncm), the groups T2 and G2 (screws tightened 20 times to 20 Ncm) and the groups T3 and G3 (screws tightened 10 times to 30 Ncm). In the study with microCT, one screw was randomly chosen from each of the groups described above to perform the scanning by microCT. RESULTS: When comparing the type of screw material using stereoscopic microscopy, no statistically significant differences were found (p > 0.05). Contrarily, different number of successive grips and different torque value showed statistically significant differences in the head section of the retaining screws (p < 0.05). The observation by microCT showed the torque applied is crucial to the head deformation in titanium screws. In gold-plated screws the successive tightening appears to be pivotal. CONCLUSION: Titanium and gold screws tend to behave similarly. By increasing the tightening cycles and the torque values of protocols greater levels of deformations can be expected. In general, microCT data showed better results for gold-plated titanium alloy. CLINICAL SIGNIFICANCE: To control severe screw head deformation and the impossibility of untightening the implant's restoration, clinicians should avoid extreme torque values and prevent surpassing 10 tightening cycles.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Dente Suporte , Análise do Estresse Dentário/métodos , Microtomografia por Raio-X , Titânio , Microscopia , Ligas de Ouro , Ligas , Ouro
11.
Rev. Odontol. Araçatuba (Impr.) ; 43(2): 49-54, maio-ago. 2022.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1362035

RESUMO

Overdenture é uma prótese total que se caracteriza por usar apoios retentivos para que aumente sua estabilidade e retenção na cavidade bucal, gerando assim menor desconforto ao paciente e melhor adaptação. A Prótese overdenture dentossuportada necessita de elementos dentais remanescentes com canais tratados endodonticamente e que possuam suporte periodontal adequado. O objetivo deste relato de caso clínico é expor a sequência de confecção de uma prótese overdenture dentossuportada maxilar associada a uma prótese total convencional mandibular, com os passos clínicos detalhados por meio de uma abordagem teórica e visual. Esse tipo de reabilitação favorece a adaptação do paciente à nova condição, visto que o uso de próteses totais convencionais pode causar certo desconforto ao paciente devido à falta de retenção e estabilidade. Essa manutenção dos dentes remanescentes favorece à manutenção óssea e a futura decisão do paciente em optar pela instalação de implantes dentários, podendo confeccionar próteses implantorretidas (overdentures) ou implantossuportadas (protocolo).O Paciente demonstrou-se satisfeito com o resultado estético e funcional após a instalação da prótese concretizando que o tratamento é viável(AU)


Overdenture is a denture that utilizing retentive supports for increase stability and retention in oral cavity. The tooth-supported overdenture require dental elements with root canal therapy and good periodontal support. The aim of this study is to report the confection of a maxillary tooth-supported overdenture associated with mandibular denture and your clinical steps. This rehabilitation promotes the patient's adaptation the new condition, since the use of conventional dentures may cause discomfort due to lack of retention and stability. The preservation of dental elements promotes bone maintenance and forthcoming decision of the patient in the installation of dental implants that can choose implantretained or implant-supported prosthesis. Patient was satisfied with aesthetic and functional result after installation of prosthesis(AU)


Assuntos
Humanos , Masculino , Retenção de Dentadura , Prótese Total , Revestimento de Dentadura , Retenção em Prótese Dentária , Prótese Dentária
12.
BMC Oral Health ; 22(1): 286, 2022 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-35836169

RESUMO

BACKGROUND: Several devices have been developed to measure implant-bone stability as an indicator of successful implant treatment; these include Osstell®, which measures the implant stability quotient (ISQ), and the more recent AnyCheck®, which relies on percussion for the implant stability test (IST). These devices make it possible to measure implant stability. However, no studies have compared the performance of AnyCheck® and Osstell® (i.e., IST and ISQ values) in clinical practice. Therefore, this study aimed to determine the correlation between primary and secondary implant stability using the Osstell® and AnyCheck® devices. METHODS: Ten patients (7 women; age [mean ± standard deviation]: 49.1 ± 13.3 years) with partially edentulous jaws who received a total of 15 implants were included. IST (AnyCheck®) and ISQ (Osstell®) values were measured immediately after implantation and at 1, 2, 3, 4, and 6 weeks post-implantation. Each measurement was performed three times, and the average value was used as the result. The correlation between measurements obtained using the two devices was determined using Spearman's rank correlation coefficient. RESULTS: The IST values ranged from 79.1 ± 2.87 to 82.4 ± 2.65. The ISQ values ranged from 76.0 ± 2.8 to 80.2 ± 2.35. Spearman's rank correlation coefficient was r = 0.64 immediately after implantation, r = 0.29 at 1 week, r = 0.68 at 2 weeks, r = 0.53 at 3 weeks, r = 0.68 at 4 weeks, and r = 0.56 at 6 weeks. A positive correlation was found in all cases, except at week 1 when the correlation was weak; the IST and ISQ values decreased the most during the first postoperative week and increased during the second week. The IST values were also slightly higher at all measurement points. CONCLUSION: The ability to assess implant stability without removing the abutment during healing is essential for determining the timing of loading without the risk of bone resorption. The results of this study suggest that AnyCheck® is useful for determining primary and secondary implant stability.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Adulto , Osso e Ossos , Implantação Dentária Endóssea/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Osseointegração , Percussão , Vibração
13.
Clin Oral Investig ; 26(11): 6521-6530, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35804172

RESUMO

OBJECTIVE: Resonance frequency analysis (RFA) provides an evaluation of implant stability over time. This analysis is a non-invasive, precise, and objective method. Several studies compare the RFA system with other devices. However, few investigations analyze repeatability and reproducibility between different operators. The aim of this study was to evaluate the intra- and inter-operator concordance of the Osstell® ISQ. MATERIAL AND METHODS: RFA measurements were performed with Osstell® ISQ in a total of 37 implants placed in 21 patients. At the time of implant placement, 6 measurements per implant were taken by three different experienced operators. Three measurements were carried out consecutively and three by removing and placing the SmartPeg-Osstell® to assess intra-operator and inter-operator agreement. RESULTS: Intra-operator concordance according to the intraclass correlation coefficient (ICC) showed high concordance. The ICC values were higher than 0.9 (p < 0.0001) for consecutive measures and alternative measures, being almost perfect of Landis & Koch classification. For inter-operator concordance The ICC was 0.709 (p < 0.0001) and 0.670 (p < 0.0001) for consecutive and alternative measures, respectively, both estimates being in the substantial category. In torque and ISQ values, no statistically significant differences were observed when operators and measurements were compared. CONCLUSIONS: Osstell® ISQ system was stable both in intra-operator and inter-operator measurements. This device has excellent repeatability and reproducibility, demonstrating reliability to measure the stability of dental implants. CLINICAL RELEVANCE: Resonance frequency analysis (RFA) is a non-invasive, objective, and reliable diagnostic method to determine the ideal moment to load the implant, as well as to predict possible failures.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Humanos , Análise de Frequência de Ressonância , Reprodutibilidade dos Testes , Estudos Prospectivos , Estudos Transversais , Vibração , Implantação Dentária Endóssea , Osseointegração
14.
Int J Oral Maxillofac Implants ; 37(3): 543-548, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35727246

RESUMO

PURPOSE: The primary stability of dental implants is one of the most crucial factors for providing long-term success of osseointegration. Vertical deficiencies, such as those due to maxillary sinus pneumatization, may cause a severe vertical limitation to residual bone height. This study aimed to examine the primary stabilization of implants without apical contacts. MATERIALS AND METHODS: Eighty bone-level implants (4.1-mm diameter/10-mm length) were placed into polyurethane test blocks without apical contacts. According to coronal bone-to-implant contact, groups were set as 4, 6, 8, and 10 mm, respectively. Resonance frequency analysis (RFA) using a SmartPeg was performed separately toward the transversal and horizontal axes by two independent researchers. Data were statistically compared for interobserver and among groups. RESULTS: Interobserver reliability varied from moderate to excellent (intraclass correlation coefficient [ICC]: 0.629 to 0.985). There were no significant differences among the 6 mm, 8 mm, and 10 mm groups, although the 4 mm group showed the significantly lowest stability (P < .001). Transversal and longitudinal measurements of the same groups did not show a parallel correlation statistically. CONCLUSION: RFA values may be affected by the finger torque in tightening of the SmartPeg among different researchers. Fully placed implants did not significantly show the highest stability among various apically contactless groups. Consequently, RFA should not be used alone to evaluate primary stability for implants without an apical contact.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Osseointegração , Reprodutibilidade dos Testes , Análise de Frequência de Ressonância , Torque , Vibração
15.
Clin Implant Dent Relat Res ; 24(4): 444-454, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35580961

RESUMO

INTRODUCTION: There are several factors that greatly influence implant stability with implant design being a paramount factor; however, few studies investigate its impact. AIM: To investigate the implant stability in relation to two different implant designs, a cylindrical shaped single-threaded design (CS/ST) and a tapered shaped double-threaded design (TS/DT) using resonance frequency analysis over the first 8 weeks after implantation. MATERIALS AND METHODS: Twenty-eight implants were randomly allocated using computer-generated random numbers into two groups and were placed as single tooth implant in the posterior arch in human jaw as specimens. iCAT™ CBCT scan (Hatfield, PA) was used to determine the bone density according to Misch's Bone classification. The osseotomy sites were prepared and implants were placed with guided surgical template by inexperienced surgeons which were prepared with the same implant planning software (3shape® implant studio). The implant stability was measured using the resonance frequency analysis Osstell® ISQ (Osstell AB, Sweden) on the implant level over the first 8 weeks at three different time intervals. A mean implant stability quotient (ISQ) value was recorded at each measurement time points. The first ISQ of each implant recorded at the time of implant placement were considered as baseline and were the so-called primary stability. RESULTS: All 28 dental implants were analyzed. A similar pattern of implant stability changes was observed in both implant designs. A significant decreased was found at the first 4 weeks after implantation (p < 0.05) before ascending to maximum cumulative stability by the eighth week (p < 0.05). Between the two groups, TS/DT group had a higher mean ISQ values than that of the CS/ST group at all three observation periods but did not reach statistical significance (p = 0.69). Regarding different types of bone, TS/DT showed a significant difference in mean ISQ values in D4 bone. To date, all 28 implants are in function with no failure/and or complications. CONCLUSIONS: The difference in implant design did not significantly influence the implant stability. TS/DT shows superiority over CS/ST when placed in D4 bone and offer a significant advantage due to their positive bounce back of the ISQ values by the eighth week after implant installation. CLINICAL TRIAL REGISTRATION: TCTR20211020005.


Assuntos
Implantes Dentários , Cirurgiões , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Humanos , Projetos Piloto , Análise de Frequência de Ressonância
16.
Clin Exp Dent Res ; 8(4): 1002-1007, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35618682

RESUMO

OBJECTIVES: Complete cleaning of temporary cement before permanent cementation of cement-retained implant-supported prosthesis (CISP) when recementing the crown is critical. This study evaluated the effect of different cleaning methods for removing traces of temporary cement on the final tensile bond force (TBF) of CISP recemented with resin cement. MATERIALS AND METHODS: Seventy computer-aided design/computer-aided manufacturing metal implant-supported copings were prepared and distributed into seven groups (N = 10). Copings of six groups (60 samples) were cemented with temporary cement with eugenol and subjected to 5000 thermocycling. After debonding by a universal testing machine, the internal surfaces of the copings were cleaned using one of the six following methods: 1-an ultrasonic water bath (UW), 2-sandblasting, then washing with water (SW), 3-sandblasting and an ultrasonic water bath (SUW), 4-an ultrasonic isopropyl alcohol bath (UA), 5-sandblasting, then washing with isopropyl alcohol (SA) or 6-sandblasting and an ultrasonic isopropyl alcohol bath (SUA). Then the subjects were subsequently cemented by dual-cure self-adhesive resin cement. In the seventh group (control, N = 10), the copings were cemented by dual-cure self-adhesive resin cement without the temporization phase. The TBF was tested using a universal testing machine with a cross-head speed of 1 mm/min. Two-way analysis of variance (ANOVA) and post-hoc Tamhane tests were used for statistical analysis at a significance level of α = .05. RESULTS: The maximum mean of TBF value was observed in SUA group (845 ± 203 N), and the minimum was observed in the temporary cement group (49 ± 20 N). All groups which were cleaned with isopropyl alcohol showed significantly higher TBF values compared with those cleaned with water. CONCLUSIONS: Cleaning of the inner surface of metal copings after debonding with sandblasting and isopropyl alcohol results in the highest value of TBF by eliminating the effect of remaining eugenol and removing traces of temporary cements.


Assuntos
Implantes Dentários , Cimentos de Resina , 2-Propanol , Adaptação Psicológica , Resinas Compostas , Cimentos Dentários/química , Materiais Dentários/química , Retenção em Prótese Dentária/métodos , Análise do Estresse Dentário , Eugenol , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Água
17.
Int J Oral Maxillofac Implants ; 37(2): 339-345, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35476863

RESUMO

PURPOSE: To evaluate the use of a new resin metal opaquer on the surface of titanium abutments, in combination with two luting agents, and its effect on the retentive strength of implant-supported zirconia copings. MATERIALS AND METHODS: Sixty customized titanium abutments were designed and fabricated with virtual design software and a milling machine. Thirty abutment specimens were coated with metal opaquers, and the others were not coated. Then, the titanium abutments were fitted into the implant analogs, and the abutment-implant analog complexes were embedded in acrylic resin blocks. Sixty CAD/CAM-fabricated zirconia copings were seated on the abutments and secured with glassionomer cement or self-adhesive resin cement. The specimens were stored in 100% humidity for 1 hour and artificial saliva for 23 hours at 37°C before thermocycling for 5,000 cycles of 5°C to 55°C with a 30-second dwell time. The retentive strength was measured using a pull-out test with a universal testing machine. The dislodgment forces were statistically analyzed via two-way analysis of variance (ANOVA). The failure modes were evaluated and categorized by examining the fracture surface. RESULTS: The metal opaquer material had a significant negative effect on retention of zirconia copings. The nonopaquer titanium abutments showed significantly (P < .05) higher retentive strength than the metal opaquer abutments. Comparing the cements, the retentive strength values of self-adhesive resin cement were significantly higher than those of glass-ionomer cement. The metal opaquer groups exhibited mostly mixed-type failures, a combination of adhesive failures and cohesive failures, whereas the nonopaquer groups showed mostly adhesive-type failures. CONCLUSION: The titanium abutments coated with the new metal opaquer material resulted in a reduction of retentive strength. Self-adhesive resin cements exhibited significantly higher retention than glass-ionomer cements.


Assuntos
Implantes Dentários , Cimentos de Resina , Adaptação Psicológica , Dente Suporte , Cimentos Dentários , Retenção em Prótese Dentária/métodos , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Teste de Materiais , Propriedades de Superfície , Titânio , Zircônio
18.
Int J Oral Maxillofac Surg ; 51(8): 1093-1100, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35339332

RESUMO

Primary stability in low-density bone is crucial for the long-term success of implants. Tapered implants have shown particularly favourable properties under such conditions. The aim of this study was to compare the primary stability of tapered titanium and novel cylindrical zirconia dental implant systems in low-density bone. Fifty implants (25 tapered, 25 cylindrical) were placed in the anterior maxillary bone of cadavers meeting the criteria of low-density bone. The maximum insertion (ITV) and removal (RTV) torque values were recorded, and the implant stability quotients (ISQ) determined. To establish the isolated influence of cancellous bone on primary stability, the implantation procedure was performed in standardized low-density polyurethane foam bone blocks (cancellous bone model) using the same procedure. The primary stability parameters of both implant types showed significant positive correlations with bone density (Hounsfield units) and cortical thickness. In the cadaver, the cylindrical zirconia implants showed a significantly higher mean ISQ when compared to the tapered titanium implants (50.58 vs 37.26; P < 0.001). Pearson analysis showed significant positive correlations between ITV and ISQ (P = 0.016) and between RTV and ISQ (P = 0.035) for the cylindrical zirconia implants; no such correlations were observed for the tapered titanium implants. Within the limitations of this study, the results indicate that cylindrical zirconia implants represent a comparable viable treatment option to tapered titanium implants in terms of primary implant stability in low-density human bone.


Assuntos
Implantes Dentários , Densidade Óssea , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Humanos , Titânio , Torque
19.
Stomatologiia (Mosk) ; 101(1): 96-102, 2022.
Artigo em Russo | MEDLINE | ID: mdl-35184542

RESUMO

The high primary stability of dental implants provides a favorable prognosis for orthopedic treatment with implant-supported structures. The importance of assessing the stability and the bone tissue surrounding the implant as a whole is due to the fact that the process of osseointegration is a structural and functional connection between the bone and the loaded surface of the implant. Determination of the dynamics of the stability of dental implants allows timely monitoring of unpredictable changes at the stages of osseointegration and remodeling of bone tissue around the implant. Currently, in addition to clinical and radiation diagnostic methods, there are generally recognized by clinicians frequency resonance analysis and periotestometry. However, there are some scientific discrepancies indicating the lack of objectivity of these methods and the impossibility of their full-fledged application without the support of radiation and clinical diagnostic methods. In addition to these methods, there are many experimental and less common methods in clinical practice for assessing the primary stability of implants, but with reasonable objectivity. Thus, the reasons are given that for a full assessment of the relationship between the efforts exerted on implants and their movements in the space of bone tissue, devices are needed that reflect the stability and density of the contact of the implant with bone tissue in physical quantities. In particular, methods based on lasers, sound, quantitative ultrasound, and others have found experimental practical application. The ultrasound method of assessing the primary stability of the implant is estimated as the most promising, since it allows you to demonstrate the results of studies in certain physical quantities, as well as to compare these results with histomorphological indicators of osseointegration of dental implants.


Assuntos
Implantes Dentários , Implantação Dentária Endóssea/métodos , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Humanos , Osseointegração , Ultrassonografia , Vibração
20.
PLoS One ; 17(1): e0262582, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35041706

RESUMO

This study aimed to evaluate the effects of two types of provisional resin cements on the color and retentive strength of two different all-ceramic restorations cemented onto customized zirconia abutments. Forty-two crowns were made of monolithic zirconia and lithium disilicate ceramics (n = 21 per group) and cemented on customized zirconia abutments by using two provisional resin cements of TempBond Clear and Implantlink Semi, and TempBond serving as the control (n = 7 per cement subgroup). The specimens' color was measured before and after cementation and after thermocycling. The color difference was calculated by using CIEDE2000 formula (ΔE00). The tensile force was applied to assess the retentive strength. Kruskal-Wallis, Dunn's post-hoc, and Mann-Whitney non-parametric tests were used to compare ΔE00(1) and ΔE00(2) and two-way ANOVA followed by one-way ANOVA and Tukey's HSD post hoc test and T-test were used to compare retentive strength between subgroups. In the lithium disilicate group, ΔE00 of the control subgroup (TempBond) was significantly higher than that of Implantlink Semi cements subgroup (P = 0.001). But, in the monolithic zirconia group, ΔE00 of the control subgroup (TempBond) was significantly higher than that of Implantlink Semi (P = 0.020) and TempBond Clear cements (P = 0.007). In the monolithic zirconia group, the control subgroup (TempBond) was significantly more retentive than TempBond Clear (P = 0.003) and Implantlink Semi cement (P = 0.001). However, in the lithium disilicate group, Implantlink Semi cement was significantly more retentive than TempBond Clear (P = 0.019) and TempBond (control) (P = 0.001). The final color of both restorations was significantly affected by the provisional resin cement type. The retentive strength was influenced by both the type of cement and ceramic.


Assuntos
Cerâmica/química , Cor , Dente Suporte , Retenção em Prótese Dentária/métodos , Teste de Materiais/métodos , Cimentos de Resina/química , Zircônio/química , Cimentação , Desenho Assistido por Computador , Porcelana Dentária/química , Humanos , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...